Bland–Altman Plot
Variant: Standard
Made-up data, for demonstration only
Variants
4 types · click one to see it in the frame above- Difference from standard
- The recommended type; use it as a starting point
- Use when
- Check whether two measurement methods agree closely enough
Bland–Altman Plot is a scatter chart that checks whether two measurement methods agree. The horizontal axis is the average of the two methods and the vertical axis is their difference. This example compares a new blood pressure monitor with a standard monitor in 50 people (made-up data).
How to read a Bland–Altman Plot
- Each point is one person measured with both devices. The horizontal axis is the average blood pressure of the two devices (mmHg). The vertical axis is the difference between the new device and the standard device.
- The middle line is the bias. It is the mean of the differences. If it is positive, the new device reads higher than the standard on average. If it is negative, it reads lower.
- The two dashed lines are the limits of agreement. They sit at the mean difference plus and minus 1.96 standard deviations. Most differences should fall between them.
- Judge by this range. The devices can replace each other only if the range falls within a limit agreed in advance, such as a difference of no more than a set number of mmHg.
- Look at the pattern of points. If the differences get wider as the values rise, the disagreement depends on the level of the measurement, and you need to look further.
- Try the "Highlight points outside range" variant to see which people the two devices disagree on unusually.
When to use it
- You compare a new device or method with an existing one. This chart was designed for that.
- You need both the bias and the width of the differences, not just one number.
- You want to check whether the differences depend on the level of the value.
When not to use it
- You want the general relationship between two variables. Use a Scatter Plot.
- The differences are far from normally distributed, or the spread grows with the level. The mean ±1.96 SD formula for the limits may not fit. Check the shape of the data and pick an estimation method that matches.
- There are more than two devices. Compare them pair by pair, or use another method.
- Readers are not used to statistics. Explain it with plain numbers, such as "within X for 95% of people".
Common mistakes
1. Using correlation instead of agreement
Two devices can be highly correlated and still differ by a large, constant amount. Agreement means looking at the differences.
2. Not setting an acceptance limit in advance
The limits can only be called acceptable when compared with a threshold that was agreed before looking at the data.
3. Assuming the standard device has no error
The device used as the standard also has measurement error. The differences contain the error of both devices.
4. Flipping the direction of the difference
State that it is new − standard, so the sign of the bias can be interpreted.
5. Using axes that do not cover all the points
Check that points outside the range are not cut off.
Compared with similar charts
| Chart | How it differs | Choose it when |
|---|---|---|
| Bland–Altman Plot | Difference against average | You check agreement between two measurement methods |
| Scatter Plot | Method 1 value against method 2 value | You look at the relationship |
| Error Bar | A value with an interval | You show the uncertainty of one value |
| Control Chart | Tracks a process over time | You check for abnormal behaviour over time |
History and development
The chart became widespread in medical statistics through the work of J. Martin Bland and Douglas G. Altman. It has another name, the Tukey mean-difference plot, after John Tukey.
Frequently asked questions
Are the limits of agreement a confidence interval?
The limits show the range in which most differences between the two systems fall. The confidence in the limits themselves is a separate matter.
What is another name for this chart?
The Tukey mean-difference plot, after John Tukey.
How many pairs of data do I need?
There is no fixed number. This example uses 50 pairs. The fewer pairs you have, the less stable the limits are.
References
- Bland–Altman plot · Wikipedia · en.wikipedia.orgUsed to confirm: the definition and basic facts of the Bland–Altman plot
- Statistical methods for assessing agreement between two methods of clinical measurement · Bland and Altman · pubmed.ncbi.nlm.nih.govUsed to confirm: the original 1986 paper and why correlation is not enough to measure agreement
- Assessing Agreement between Methods of Measurement · Bland and Altman · ora.ox.ac.ukUsed to confirm: the assumptions about the distribution of differences and constant spread across levels
Last updated 28 Nov 2026
In the same group
- KPI Card / Big Number
- Gauge / Speedometer
- Progress Bar
- Pareto Chart
- Control Chart
- Run Chart
- Candlestick / OHLC
- Depth / Order Book Chart
- ROC Curve
- Confusion Matrix
- Cumulative Gains Chart
- Forest Plot
- Volcano Plot
- Ternary Plot
- Contour / Surface Plot
- 3D Scatter Plot
- Table + Conditional Formatting
- Burndown Chart
- Kaplan–Meier
- Pivot Table / Matrix
- KPI Tree / Driver Tree
- Radial Bar / Progress Ring
- Table with Sparklines
- RAG Scorecard
- Data Table